DC2 Key Attributes
- Available in either open chassis, totally enclosed NEMA Type 12 or NEMA 4X
- Operates from either local or remote operator controls for added mounting flexibility
- All circuitry - sequencing, regulator and terminals - packaged on a single, accessible surface mount design printed circuit board
- Jumper reconnections adapt standard controllers to match:
| - |
Line voltage, either 115 or 230 VAC, 50 or 60 Hz. |
| - |
Desired feedback, either armature voltage or motor driven DC tachometer for non-reversing models only. |
| - |
Tachometer requirements: 7 VDC OR 20.8 VDC or 20.8 VDC per 1000 RPM designs |
| - |
"S" curve or linear acceleration |
| - |
Zero speed operation |
- Separately adjustable maximum and minimum speeds set speed limits
- Adjustable current limit protects machinery, wiring and drive
- Adjustable IR drop compensation improves speed regulation when using armature voltage feedback
- Adjustable acceleration and deceleration rates for smooth starts, stops and speed changes
- 20:1 constant torque speed range
- 30:1 constant torque speed range with tachometer feedback
- Full-wave, half-control power conversion with back diode for efficient power conversion, smooth armature current waveforms and cool motor operation over wide operating speed ranges
- Built-in half-wave field supply for operation of wound field motors
- Built-in surge suppressor
- Relay in control circuit prevents automatic restarting after power outage
- Overload protection provided by motor thermostat
- NEMA 4 Controls are F.D.A./U.S.D.A. approved
|
|