AC Drives |
AutoMax Network Communication BoardA powerful, economical method for interfacing the GV3000 to AutoMax |
|
|
The AutoMax network communication board is designed to enable communication between the GV3000 A-C Drive and the AutoMax real-time Distributed Control System NETwork (DCS-NET). A GV3000 drive can be controlled, tuned, and monitored by way of this high speed (875K Baud) network link. Drive data is predefined on DCS-NET through fixed memory mapping to ensure minimal programming. A simple ribbon cable connects the GV3000 regulator to the communication board. Because the board mounts internally to the drive, no additional cabinet space is required. FunctionDCS-NET is a master/slave control network designed for high speed coordination between multiple drive sections. Data is transmitted and received over a single coaxial cable. DCS-NET supplies the link to connect multiple AutoMax racks, personal computers, Reliance AC and DC drives and operator interface terminals to form a distributed control system. The network contains one master and up to 55 slave drops. FeaturesControlFunctional control of the GV3000 AC Drive is accomplished through DCS-NET. Typical network control includes: start/stop, Fwd/Rev direction, Run/Jog mode and speed or torque reference. TuningThe GV3000 drive can be adaptively tuned to its current process. This can include speed loop proportional or integral gain, reference trim or draw gain, and acceleration or deceleration rates. MonitoringEven if a GV3000 is controlled through hardwired inputs or keypad control, monitoring of the drive is possible. Fedbacks such as speed and torque feedback, current, and fault diagnostics can be observed and trended. ConfigurationsParameter P.061 allows the user to select the network configuration for each GV3000 AC drive. Configurations are provided in two forms: Basic Drive Connection and Full Drive Connection. BasicConfigured in the basic connection, a GV3000 will occupy a single slave drop. For high density applications, this configuration will allow up to 48 drives to be connected on a single network. Network data is comprised of commonly used parameters and diagnostic information. FullFor network access to all parameters and operating variables, the GV3000 can be configured as a full drive connection. This connection type will occupy three slave drops, allowing up to 18 drives to be placed on a single network. Specifications
GV3000 Setup
|
| Parameter | Description |
|---|---|
| P.000 | Control source (LOCL, rE, PC, OP) |
| P.060 | Drop number assignment (1-55) |
| P.061 | Network connection type (0=Basic,1=Full) |
| P.062 | Communication loss response (0=IET, 1=Hold, 2=Terminal) |
| P.063 | Reference select (0=Direct, 1-8=Broadcast) |
| 57C380 | - | Communications Passive Tap |
| 57C381 | - | Communications Module to |
| Passive Tap Cable | ||
| 57C404 | - | AutoMax Network Communications |
| Module | ||
| 57C445 | - | AutoMax PC Link Module |
| 47C70 | - | Coax BNC TEE Connector |
| 45C71 | - | Coax BNC 75 OHM Terminating Load |
|
Document D-2895 |
| Note: |
This material is not intended to provide operational instructions. Appropriate Reliance Industrial Company instruction manuals and precautions should be studied prior to installation, operation, or maintenance of equipment. |