IDENTIFICATION
In most instances, the following information will help identify
a motor:
1. Frame designation (actual frame size in which the motor is built).
2. Horsepower, speed, design and enclosure.
3. Voltage, frequency and number of phases of power supply.
4. Class of insulation and time rating.
5. Application
INDUCTANCE
The characteristic of an electric circuit by which varying current
in it produces a varying magnetic field which causes voltages in the same
circuit or in a nearby circuit.
INDUCTION MOTOR
An induction motor is an alternating current motor in which
the primary winding on one member (usually the stator) is connected to
the power source and a secondary winding or a squirrel-cage secondary
winding on the other member (usually the rotor) carries the induced current.
There is no physical electrical connection to the secondary winding, its
current is induced.
INERTIAL LOAD
A load (flywheel, fan, etc.) which tends to cause the motor shaft
to continue to rotate after the power has been removed (stored kinetic
energy). If this continued rotation cannot be tolerated, some mechanical
or electrical braking means must normally be applied . This application
may require a special motor due to the energy required to accelerate the
inertia. Inertia is measured in either lb.ft.2 or OZ.jn.2
Inertia reflected to the shaft of the motor = (Load RPM) 2/Motor
RPM
INSULATOR
A material which tends to resist the flow of electric current
(paper, glass, etc.) In a motor the insulation serves two basic functions:
1. Separates the various electrical components from one another.
2. It protects itself and the electrical components from attack of contaminants
and other destructive forces.
INSULATION SYSTEMS
Five specialized elements are used, which together constitute
the motor's INSULATION SYSTEM. The following are typical in an AC motor:
1. TURN-TO-TURN INSULATION between separate wires in each coil. (Usually
enamel on random wound coils of smaller motors - tape on "form wound"
coils of larger motors.)
2. PHASE-TO-PHASE INSULATION between adjacent coils in different phase
groups. (A separate sheet material on smaller motors - not required on
form wound coils because the tape also performs this function.)
3. PHASE-TO-GROUND INSULATION between windings as a whole and the "ground"
or metal part of the motor. (A sheet material, such as the liner used
in stator slots, provides both di-electric and mechanical protection.)
4. SLOT WEDGE to hold conductors firmly in the slot.
5. IMPREGNATION to bind all the other components together and fill in
the air spaces. (A total impregnation, applied in a fluid form and hardened,
provides protection against contaminants.
INSULATION CLASS
Since there are various ambient temperature conditions a motor
might see and different temperature ranges within which motors run and
insulation is sensitive to temperature; motor insulation is classified
by the temperature ranges at which it can operate for a sustained period
of time.
There are four common classes:
| Class |
AC Motor DC. Motor W/1.00 S.F.
Max. Total Temperature Range
(Including Ambient and Temperature
110f Hot Spot) Range |
|
DC Motor Total
Temperature Range |
| A |
105fC |
A |
110f C |
| B |
130fC |
B |
140f C |
| F |
155fC |
F |
170f C |
| H |
180fC |
H |
195f C |
When a motor insulation class is labeled on the nameplate the total insulation
system is capable of sustained operation at the above temperature.
INTERMITTENT DUTY
A requirement of service that demands operation for alternate
intervals of (1 ) load and no load; or (2) load and rest; or (3) load,
no load and rest; such alternate intervals being definitely specified.
INTERPOLES
An auxiliary set of field poles carrying armature current to
reduce the field flux caused by armature reaction in a DC motor.
INVERTER
An electronic device that converts fixed frequency and fixed
voltages to variable frequency and voltage. Enables the user to electrically
vary the speed of an AC motor.
I2R
Losses due to current flowing in a conductor caused by resistance
(equals the current squared times the resistance.)
|