AC
Motors |
1/3 to 2 HP
Designed for long life and reliable operations in severe industrial applications |
 |
| Standard
Features | Specifications | Performance
Data |
These motors are totally enclosed and sealed
to minimize the possibility of dirt, dust, water, or other contaminates
from entering the motor and shortening the life of the motor. The SXT
motor is ideal in applications where standard open drip-proof or totally
enclosed motors do not provide adequate protection. They are built extra
tough for life in moist, contaminated environments found in chemical plants,
petroleum refineries, paper mills and other demanding industrial installations.
Standard
Features
- Frame - Heavy gauge steel with full seam weld. Optimum thickness
for better heat dissipation. Frame-to-end-shield fits extra long, turned,
and sealed with permatex® to protect motor internals from contaminants.
Frame zinc chromate plated and primed with acrylic enamel primer.
- End Shields - Cast iron to provide extra strength and corrosion
resistance. Epoxy primed.
- Drains - "T" drain in end shield provides drainage
of any condensation and moisture collected inside motor and on windings.
Fan cooled motors have drain hole in fan end providing an additional exit
for moisture.
- Base - Heavy duty steel welded to frame. Base zinc chromate
plated and primed with acrylic enamel primer.
- Rotor - Cast aluminum with integrally cast fins for excellent
cooling. Keyless design, heat shrunk to shaft, turned for proper air gap
and dynamically balanced. Coated with epoxy polyamide primer to resist
corrosion. Designed for a superior, more efficient and rugged electrical
design.
- Stator - Specially treated class "F" and "H"
wire used with full slot liner material. Coil heads laced for improved
mechanical strength. Stator tested before and after assembly providing
optimum electrical integrity.
- Insulation - Non-hygroscopic, double dipped and baked insulation
assures superior electrical strength and integrity. Phase insulation
included for inverter duty applications on three-phase motors.
- Hardware - Zinc chromate plated, high strength, with hex heads.
Plating provides exceptional corrosion protection.
- Seals - Lipseals on both ends.
- Bearings - Double sealed, oversized and permanently lubricated
for improved bearing life. Rugged to hold up in tough applications.
- Conduit Box - Oversized, top mounted, conduit box with F1/F2
conduit connection and grounding lug for ease of installation and safety
(F1/F2 conduit box in the end shield for TENV). Conduit box and lid are
gasketed to protect the interior of the motor from life limiting contaminates.
- Shaft - High strength, 416 stainless steel. Offers better resistance
to abrasive and corrosive materials.
- Nameplate - Stainless steel for added life in corrosive atmospheres.
Provides ease of identification.
- Connection Diagram - Permanently attached to motor.
- Fan - Antistatic, bidirectional, corrosion resistant polypropylene.
Provides superior cooling with reduced losses due to air movement. Keyed
and clamped to prevent movement on the shaft.
- Single-phase - Electronic starting switch mounted in conduit
box (or on end shield for TENV) providing convenience and reliability.
- Finish - Exterior is coated with an acrylic enamel finish coat
for superior corrosion resistance, durability and extended service life.
- Leads - Permanently marked providing fast identification.
- Certifications - U.L.® component recognition and CSA®
approved.
- Energy Saving Design - Provided by electrically matched rotor
and stator which reduce primary and secondary losses. Also available in
energy efficient designs for superior savings.
Specifications
| Horsepower |
1/3 to 2 |
| Speed(1) |
3600, 1800, 1200, 900 RPM |
| Enclosure |
Totally Enclosed, Fan Cooled or Totally Enclosed Non-vent |
| Frame |
56, 140T |
| NEMA Design |
B |
| Power Supply |
Single-phase, 60 Hz, 115/230 or Three-phase, 60 Hz, 208-230/460 (A wide
range of other frequencies and voltages are also available.) |
| Insulation |
Class F |
| Duty |
Continuous |
| Ambient |
40°C |
| Service Factor |
1.15 |
(1) Single-phase 900 RPM not available.
Performance
Data
Single-Phase
| HP |
Full Load
RPM |
Encl. |
Type |
Amperes @
230 V |
Efficiency Load(1) |
Power Factor Load |
S.F. |
Torque, Lb. Ft. |
Perf. Data
Design |
| FL |
LR |
Code |
4/4 |
3/4 |
2/4 |
4/4 |
3/4 |
2/4 |
FL |
BD |
LR |
| 1/3 |
1725 |
TENV |
CS |
2.40 |
13.50 |
M |
71.0 |
69.0 |
61.0 |
67.0 |
60.0 |
52.0 |
1.15 |
1.02 |
3.13 |
3.00 |
M3135 |
| 1140 |
TENV |
CS |
3.50 |
15.20 |
M |
63.0 |
61.0 |
52.0 |
50.0 |
44.0 |
36.0 |
1.15 |
1.53 |
4.04 |
5.08 |
M3151 |
| 1/2 |
3600 |
TEFC |
CS |
2.80 |
18.85 |
K |
75.3 |
72.7 |
66.9 |
79.0 |
73.5 |
64.2 |
1.15 |
0.74 |
2.00 |
2.33 |
M2696 |
| 1725 |
TENV |
CS |
3.20 |
18.50 |
L |
75.0 |
73.0 |
68.0 |
68.0 |
60.0 |
50.0 |
1.15 |
1.49 |
3.91 |
5.25 |
M3105 |
| 1140 |
TEFC |
CS |
4.70 |
22.50 |
L |
61.0 |
59.0 |
52.0 |
58.0 |
50.0 |
41.0 |
1.15 |
2.27 |
5.24 |
6.50 |
M3131 |
| 3/4 |
3450 |
TEFC |
CS |
4.70 |
26.20 |
K |
72.0 |
71.0 |
66.0 |
76.0 |
70.0 |
62.0 |
1.15 |
1.12 |
2.56 |
3.06 |
M2649 |
| 1725 |
TEFC |
CS |
5.50 |
29.00 |
K |
70.4 |
69.6 |
63.6 |
69.5 |
60.7 |
49.5 |
1.15 |
2.25 |
5.81 |
7.69 |
M6983 |
| 1140 |
TEFC |
CH |
4.45 |
25.00 |
J |
76.0 |
73.6 |
67.3 |
73.1 |
66.9 |
57.5 |
1.15 |
3.38 |
8.33 |
10.00 |
M4575 |
| 1 |
3450 |
TEFC |
CS |
5.60 |
34.30 |
J |
70.0 |
69.0 |
65.0 |
78.0 |
74.0 |
63.0 |
1.15 |
1.45 |
3.58 |
3.56 |
M2651 |
| 1725 |
TEFC |
CS |
6.80 |
34.30 |
K |
72.0 |
70.0 |
64.0 |
67.0 |
58.0 |
47.0 |
1.15 |
3.01 |
7.50 |
10.00 |
M2688 |
Three-Phase
| HP |
Full Load
RPM |
Encl. |
Type |
Amperes @
460 V |
Efficiency Load(1) |
Power Factor Load |
S.F. |
Torque, Lb. Ft. |
Perf. Data
Design |
| FL |
LR |
Code |
4/4 |
3/4 |
2/4 |
4/4 |
3/4 |
2/4 |
FL |
BD |
LR |
| 1/4 |
1725 |
TENV |
P |
0.65 |
3.50 |
N |
65.3 |
59.7 |
51.4 |
55.3 |
48.4 |
39.1 |
1.15 |
.750 |
3.33 |
2.29 |
M2922F |
| 1/3 |
1725 |
TENV |
P |
0.80 |
4.65 |
N |
69.1 |
64.4 |
55.9 |
57.3 |
48.6 |
39.5 |
1.15 |
.981 |
4.50 |
3.38 |
M2971 |
| 1/2 |
3450 |
TENV |
P |
1.17 |
11.10 |
M |
76.1 |
76.0 |
71.2 |
82.8 |
73.6 |
62.5 |
1.15 |
.750 |
2.95 |
2.41 |
M2749 |
| 1725 |
TENV |
P |
1.10 |
6.10 |
L |
74.3 |
72.1 |
66.8 |
65.7 |
56.1 |
44.0 |
1.15 |
1.50 |
5.58 |
3.92 |
M6976 |
| 3/4 |
3450 |
TENV |
P |
1.20 |
9.80 |
L |
79.0 |
78.0 |
73.0 |
82.0 |
78.0 |
68.0 |
1.15 |
1.16 |
4.23 |
3.09 |
M2957 |
| 1725 |
TENV |
P |
1.25 |
10.00 |
M |
74.0 |
66.0 |
56.0 |
74.0 |
66.0 |
56.0 |
1.15 |
2.25 |
10.69 |
8.00 |
M2925 |
| 1140 |
TEFC |
P |
1.60 |
7.15 |
J |
74.0 |
72.0 |
68.0 |
66.0 |
57.0 |
46.0 |
1.15 |
3.43 |
10.00 |
7.75 |
M2948 |
| 1 |
3450 |
TENV |
P |
1.50 |
10.75 |
K |
80.0 |
80.0 |
76.0 |
87.0 |
82.0 |
73.0 |
1.15 |
1.50 |
5.49 |
4.08 |
M2994 |
| 1730 |
TEFC |
P |
2.20 |
12.90 |
L |
75.0 |
72.0 |
66.0 |
60.0 |
52.0 |
42.0 |
1.15 |
3.03 |
13.30 |
10.00 |
M2921 |
| 1725 |
TENV |
P |
1.60 |
12.30 |
M |
81.0 |
81.0 |
77.0 |
78.0 |
70.0 |
59.0 |
1.15 |
3.01 |
13.30 |
12.50 |
M2968 |
| 1140 |
TEFC |
P |
2.20 |
9.95 |
J |
74.0 |
73.0 |
66.0 |
58.0 |
49.0 |
39.0 |
1.15 |
4.56 |
14.90 |
10.80 |
M141 |
| 1-1/2 |
3450 |
TEFC |
P |
2.20 |
2.03 |
H |
79.5 |
78.5 |
74.8 |
84.6 |
80.0 |
70.6 |
1.15 |
2.24 |
8.19 |
6.25 |
M6742 |
| 1725 |
TEFC |
P |
2.80 |
15.80 |
K |
78.5 |
76.0 |
70.3 |
64.7 |
55.0 |
44.0 |
1.15 |
4.51 |
16.70 |
12.90 |
M2920 |
| 2 |
3450 |
TEFC |
P |
2.80 |
2.84 |
L |
79.7 |
74.8 |
67.1 |
84.3 |
76.0 |
68.0 |
1.15 |
3.04 |
11.00 |
9.38 |
M6743 |
| 1730 |
TEFC |
P |
3.20 |
21.00 |
J |
81.8 |
80.2 |
77.5 |
74.6 |
67.4 |
55.2 |
1.15 |
6.10 |
21.20 |
16.80 |
M2916 |
(1) Efficiency values based on a motor without lip
seals. SXT motors have lip seals causing efficiency to vary.
Ask for Assistance
Before you buy another AC motor, check with your Reliance sales
engineer or distributor to determine why Reliance SXT motors
are the proper choice. For further information about Reliance motor products,
contact your local Reliance sales office or authorized distributor
or call:
1-800-245-4501
Document number b2762_3
- Note: This material is not intended to provide operational instructions.
- Appropriate Reliance Industrial Company instruction manuals
and precautions should be studied prior to installation, operation, or
maintenance of equipment.
Reliance® is a trademark of Baldor.
U.L.® is a registered trademark of Underwriters Laboratories, Inc.
CSA is a registered trademark of the Canadian Standards Association.
|